Intermec NORAND 600 User Manual

Page 26

Advertising
background image

SECTION 2

Operation

2-8 NORAND

R

600 Series Industrial Mobile Computer User’s Guide

that is stored in flash memory. Erasing the registry allows

the system to use registry changes incorporated in the new

Windows CE release.

" NOTE:

Upgrading flash erases the registry and destroys previous settings.

Perform the following steps:

1. System format a PC Card with MS-DOS 6.22 or 7.00.

This requires a machine running DOS or Windows 95.

You will not be able to system format a PC Card under

Windows NT with MS-DOS. Place the appropriate HI-

MEM.SYS in the root directory. You may need a Com-

pactFlash Adapter card (P/N: 850-547-001) which al-

lows the CompactFlash card to be used in a Standard

PCMCIA card slot on your development machine.

2. Copy the entire contents of the “DriveImg” directory to

the PC Card. Place the card in the 602 Computer’s

external compact card slot.

3. Simultaneously press and hold the [GOLD], [Esc],

and [0] keys for three seconds to reset the computer.

" NOTE:

This image contains

CONFIG.SYS and AUTOEXEC.BAT files. If

you are using a development card (instead of a blank card), you will

need to merge these files into your current configuration files. The

CONFIG.SYS and AUTOEXEC.BAT files are listed on the next page.

The 602 Computer files are different only during the Flash Update

portion of the AUTOEXEC.BAT processing.

EXAMPLE:

CONFIG.SYS

device=C:\himem.sys /testmem:off /MACHINE:2

EXAMPLE:

AUTOEXEC.BAT

ECHO OFF
path .;c:\
cd WINCE
startce
:End