Indicators

Control Lamps

The EasyCoder F4 has several ways of communicating directly with
its operator: three control lamps, a display window, a membrane-
switch keyboard with 22 keys, a big “Feed” button on the printer’s
front, and a beeper. Only some of the keys are used with IPL.

The control lamps are colored LEDs (Light Emitting Diodes) and
indicate the following conditions:
Power (green):
On

Power on

Off

Power off

Ready (green):
On

Media fault detected

Flashing

Printer offl ine

Off

Printer online

Error (red):
On

System fault detected

Flashing

Printer overtemperature

Off

OK

The display window contains an LCD (Liquid Crystal Display)
with background illumination and two lines of text, each with
16 characters. It guides the operator through upgrading, startup,
and setup.