RS-232 Interface

RS-232 Port

The EasyCoder F4 has, as standard, one serial communication
interface: RS-232.

Default Communication Setup

Baud rate:

9600

Char. length

8 bits

Parity:

None

Stop bits:

1

Protocol:

XON/XOFF

To change the serial interface settings, see Chapter 6, “Setting
Up the Printer.”

Interface Cable

Computer end:

DB-9pin or DB-25pin female connector(PC)

Printer end:

DB-25pin male connector

Host

EasyCoder

F4

Host

Signal DB-9

DB-25 Signal DB-25

DB-25

Signal

1 1

1 1 shield

RXD 2 2 TXD 2 3 RXD
TXD 3 3 RXD 3 2 TXD
CTS 8 4 RTS 4 5 CTS
RTS 7 5 CTS 5 4 RTS

6

DSR

6

20

DTR

GND 5 7

Signal

GND

7 7 GND

16

+

5V

1

16

DSR 6 20 DTR 20 6 DSR

22

RI

22

1

/. The external +5V is limited to 200 mA and is automatically

switched off at overload.