Setup parameters, Serial communication, Baud rate – Intermec F4 User Manual

Page 36: Data bits, Parity, Stop bits

Advertising
background image

Intermec EasyCoder F4 – Installation & Operation IPL Version, Ed. 3

35

Chapter 6 Setting Up the Printer

Setup Parameters

Serial Communication
• Baud Rate
• Data Bits
• Parity
• Stop Bits
• Protocol

The serial communication parameters control the communication
between the printer and the connected computer or other devices on
the serial port. The serial communication parameters have no effect
on parallel communication.

Make sure the printer’s communication parameters match the setup
of the connected device or vice versa. If not, the response from the
printer to the host will be garbled.

Baud Rate

The baud rate is the transmission speed in bits per second. There
are 8 options:

• 1200
• 2400
• 4800
• 9600 (default)
• 19200
• 38400
• 57600
• 115200

Data Bits

This parameter specifies the number of bits that will define a
character.

• 7

Characters ASCII 000 to 127 decimal

• 8

Characters ASCII 000 to 255 decimal

(default)

Parity

The parity decides how the fi rmware will check for transmission
errors. There are four options:

• None (default)
• Even
• Odd
• Space

Stop Bits

The number of stop bits specifi es how many bits will defi ne the end
of a character. There are two options:

• 1

(default)

• 2

Advertising