IN CASE OF USING INTERNAL REFERENCE SIGNAL

NEED TO MODIFY

the PLL unit (bottom side) as below. Otherwise the transceiver does not work properly.

q

Unsolder connect points (CP5041) on the PLL unit.

w

Solder R5251 to the original position, or solder disconnect points (CP5251) on the PLL unit.

CONNECTION

Connect the external reference oscillator to the IC-F7000 as below.

q

w

CP5251

CP5041

External reference

IC-F7000 front panel

[REF IN]

Frequency

: 32 MHz

Level

: 2.0–8.0 V

p-p

at 15 k