5 - 1

5-1 PREPARATION

When adjusting the contents on page 5-9, a JIG CABLE (see illustration as below) is required.
Some adjustments must be performed on the “ADJUSTMENT MODE”. Entering the “ADJUSTMENT MODE”, refer to the next
page in detail.

REQUIRED TEST EQUIPMENT

SECTION 5 ADJUSTMENT PROCEDURES

EQUIPMENT

DC power supply

RF power meter
(terminated type)

Frequency counter

FM deviation meter

Digital multimeter

GRADE AND RANGE

Output voltage

: 13.8 V DC

Current capacity

: 25 A or more

Measuring range

: 1–200 W

Frequency range

: 0.5–50 MHz

Impedance

: 50

SWR

: Less than 1.2 : 1

Frequency range

: 0.1–50 MHz

Frequency accuracy : ±1 ppm or better
Sensitivity

: 100 mV or better

Frequency range

: DC–50 MHz

Measuring range

: 0 to ±5 kHz

Input impedance

: 10 M

/V DC or better

EQUIPMENT

Audio generator

Attenuator

Standard signal
generator (SSG)

DC voltmeter

Oscilloscope

AC millivoltmeter

GRADE AND RANGE

Frequency range

: 300–3000 Hz

Output level

: 1–500 mV

Power attenuation

: 50 or 60 dB

Capacity

: 150 W or more

Frequency range

: 0.5–30 MHz

Output level

: 0.1 µV–32 mV

(–127 to –17 dBm)

Input impedance

: 50 k

/V DC or better

Frequency range

: DC–20 MHz

Measuring range

: 0.01–20 V

Measuring range

: 10 mV–10 V

to [SP]

PTT

to [CONTROLLER]

[MIC] connector

to antenna connector

Speaker

FM deviation meter

Distortion meter

Audio

generator

AC millivolt

meter

Standard signal

generator

CAUTION!

DO NOT transmit while
an SSG is connected to
the antenna connector.

DC power supply

Ammeter

Attenuator

Spectrum scope

+

+

_

_

RF power meter

Frequency counter

100 load

(SWR 2 dumy load)

iF7000

RC-26

8

1

• CONNECTION