5-4 RECEIVER ADJUSTMENTS

”TOTAL GAIN”, “S-METER” and “DSC PEAK” adjustments must be performed at “ADJUSTMENT MODE”.

NOISE NULL
POINT

RECEIVER
GAIN

TOTAL GAIN

S-METER

1

1

1

1

2

• Operating frequency : 0.5 MHz
• Mode

: A3E

• Preset L209 parallel to top edge of its

chassis.

• Preset L401, L403, L404, L405 and

L801 to max. counter clockwise.

• Set the standard signal generator to

OFF (no signal output).

• Receiving

• Operating frequency : 13.9210 MHz
• Mode

: J3E

• Connect a standard signal generator

to the [ANT] connector and set as:

Frequency

: 13.9210 MHz

Level

: 0.5 µV*

(–113 dBm)

Modulation

: OFF

• Receiving

While pushing HM-146’s [CALL]
switch and RC-26’s [EMG] switch,
then turn power ON.

• Push [2] switch to enter the RX adjust-

ment mode.

• Connect a standard signal generator

to the [ANT] connector and set as:

Frequency

: 13.9210 MHz

Level

: 320 µV*

(–57 dBm)

Modulation

: OFF

• Receiving

• Set the standard signal generator to

OFF (no signal output).

• Set the standard signal generator as:

Frequency

: 13.9210 MHz

Level

: 10 mV*

(–27 dBm)

• Receiving

Front

panel

Front

panel

Connect an AC milli-
voltmeter to the [SP]
jack with a 4

dummy

load.

Connect an AC milli-
voltmeter to the [SP]
jack with a 4

dummy

load.

Minimum output

level

Maximum out-

put level

MAIN

MAIN

R217,

R218

L207,
L208,
L210,

L211

ADJUSTMENT

ADJUSTMENT CONDITIONS

UNIT

LOCATION

VALUE

UNIT

ADJUST

MEASUREMENT

ADJUSTMENT

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

• Push the [OK] switch to write the adjustment value in the memo-

ry.

• Push the [OK] switch to write the adjustment value in the memo-

ry.

• Push the [OK] switch to write the adjustment value in the memo-

ry.