5-3 PA AND FILTER UNITS ADJUSTMENT

IDLING
CURRENT
(For drive

FETs)

(For final

transistors)

SWR
DETECTOR

1

2

• Operating frequency : 12.2350 MHz
• Mode

: J3E

• Apply no audio signal to the [MIC] con-

nector.

• Disconnect J6702.
• Preset R6304 and R6412 on the PA

unit to max. counter clockwise.

• Preset R6515 on the PA unit to max.

clockwise.

• Connect a dummy load or RF power

meter to the [ANT] connector.

• Transmitting

• Transmitting

• Operating frequency : 22.0000 MHz
• Mode

: J3E

• Connect the CP7332 (FOR line) on

the FILTER unit to ground.

• Connect an audio generator to the

[MIC] connector and set as:

Frequency

: 1.5 kHz

Level

: OFF

• Transmitting

Rear

panel

Rear

panel

FIL-

TER

Connect an ammeter
(10 A) between an
external power supply
and the transceiver.

Connect an RF power
meter to the [ANT]
connector.

Connect a DC volt-
meter to the check
point, CP7331.

2.0 A

0.7 A

90 W

Minimum level

PA

Audio

gen-

erator

FIL-

TER

R6304

R6412

Output

level

C7275

ADJUSTMENT

ADJUSTMENT CONDITIONS

UNIT

LOCATION

VALUE

UNIT

ADJUST

MEASUREMENT

ADJUSTMENT

• After adjustment, connect J6701 to the PA unit.

1

2

• After adjustment, disconnect CP7332 (FOR line) on the FILTER unit from ground.