Self-diagnosis function, Specifications, Self-diagnosis function specifications – IBM P96 User Manual

Page 28: Additional information

Advertising
background image

20

Additional Information

Specifications

Picture tube

0.24 mm aperture grille pitch
19 inches measured diagonally
90-degree deflection

Viewable image size

Approx. 365

×

274 mm (w/h)

(14

3

/

8

×

10

7

/

8

inches)

18.0” viewable diagonal

Resolution

Horizontal: Max. 1600 dots
Vertical: Max. 1200 lines

Standard image area

Approx. 352

×

264 mm (w/h)

(13

7

/

8

×

10

1

/

2

inches)

Deflection frequency*

Horizontal: 30 to 107kHz
Vertical: 48 to 120 Hz
256

<

Total Line

<

2048

AC input voltage/current

100 to 240 V, 50 – 60 Hz, Max. 2.0 A

Power consumption

Max. 140 W

Operating temperature 10

°

C to 40

°

C

Dimensions

Approx. 462

Ч

462

Ч

474 mm

(w/h/d)
(18

1

/

4

Ч

18

1

/

4

Ч

18

3

/

4

inches)

Mass

Approx. 27 kg (59 lb 8 oz)

* Recommended horizontal and vertical timing condition

• Horizontal sync width should be more than 1.0 µsec.
• Horizontal blanking width should be more than

3.0 µsec.

• Vertical blanking width should be more than 450 µsec.

Design and specifications are subject to change without
notice.

Self-diagnosis Function

This monitor is equipped with a self-diagnosis function. If
there is a problem with your monitor or computer, the
screen will go blank and the u indicator will either light up
green or flash orange.

If the u indicator is green

1

Disconnect the video input cable or turn off the
connected computer.

2

Press the u button twice to turn the monitor off and
then on.

3

Press and hold the /

button for 2 seconds before

the monitor enters power saving mode.

If all four color bars appear (white, red, green, blue), the
monitor is working properly. Reconnect the video input
cable and check the condition of your computer.

If the color bars do not appear, there is a potential monitor
failure. Inform the IBM HelpCenter of the monitor’s
condition.

If the u indicator is flashing orange

Press the u button twice to turn the monitor off and
then on.

If the u indicator lights up green, the monitor is working
properly.

If the u indicator is still flashing, there is a potential
monitor failure. Inform the IBM HelpCenter of the monitor’s
condition. Be sure to note the model name and serial
number of your monitor. Also note the make and model of
your computer and video board.

u

indicator