USER RESPONSIBLE F O R V E R I F Y I N G VERSION A N D COMPLETENESS

O E M F U N C T I O N A L SPECIFICATION ULTRASTAR X P (DFHC) SSA M O D E L S 1.12/2.25 GB - 1.0" H I G H

Table 15. Maximum and Reliability Operating Temperature Limits

Maximum

Reliability

Disk Enclosure Top

158˚ F

(70˚ C)

131˚ F

(55˚ C)

Disk Enclosure Bottom

158˚ F

(70˚ C)

131˚ F

(55˚ C)

P R D F Prime Module

203˚ F

(95˚ C)

176˚ F

(80˚ C)

W D 61C40 Module

185˚ F

(85˚ C)

167˚ F

(75˚ c)

SIC Module

203˚ F

(95˚ C)

176˚ F

(80˚ C)

Microprocessor Module

194˚ F

(90˚ C)

167˚ F

(75˚ C)

VCM F E T

194˚ F

(90˚ C)

167˚ F

(75˚ C)

D C / D C Converter (CxB only)

185˚ F

(85˚ C)

167˚ F

(75˚ C)

SMP F E T

194˚ F

(90˚ C)

167˚ F

(75˚ C)

Note 1: Module temperature measurements should be taken from the top surface of the module.

Note 2: If copper tape is used to attach temperature sensors, it should be no larger than 6 square milli-
meters.

notes:

1) dimensions are in millimeters.

Figure 22. Temperature Measurement Points for All Models (top view of DE)

Source filename=OPLIMITS