ICE Series

Troubleshooting Trees

Page C7


Low Suction Pressure

NO

YES

Does

installation

meet

guidelines?

Check TXV for

moisture based

restriction

Check for correct

head pressure, see

page E10

NO

Check for refrigerant

tubing restriction,

crimps, etc.

Check Evaporator

coil separation, see

page E4

YES

YES

Go to

Troubleshooting

Tree on page

C12

Is the

machine a

remote unit?

Replace drier,

evacuate and

recharge

system

NO

NOT OK

OK

Is the water

flow over the

Evaporator

correct?

Low charge,

locate and

repair leak,

evacuate and

recharge

system

See

Troubleshooting

Tree page C18

TXV possibly

defective, see

page E3 and

page E4

Correct

restricted tubing

OK

OK

WET SYSTEM

DRY SYSTEM

NOT OK

NOT OK

Replace

defective

Evaporator

Correct

deficiency in

installation