IBM 3590 User Manual

Page 122

Advertising
background image

Table 34. FID Messages (continued)

FID

Description

Customer Action

9F

ACF or Cartridge

Problem

1.

Ensure you are using correct cartridge, 3590 only.

2.

This failure may be caused by a damaged cartridge.
Before replacing any FRUs, inspect the cartridge
that was being used when the error occurred for
physical defects. Replace the cartridge if it is
damaged.

3.

This failure may be caused by a dirty cartridge.
Look for any contamination on the sides of the
cartridge that could cause the pinch rollers to slip.
Clean or replace the cartridge if necessary.
Note:

Do not ship magazines with cartridges

loaded. The cartridges will vibrate in the magazine
slots resulting in contamination on the sides of the
cartridges that may cause this failure.

4.

Call for service if problem remains.

A0-A6

Drive Problem

Call for service

A7, A8, A9

ACF or Cartridge

Problem

1.

Ensure you are using correct cartridge, 3590 only.

2.

This failure may be caused by a damaged cartridge.
Before replacing any FRUs, inspect the cartridge
that was being used when the error occurred for
physical defects. Replace the cartridge if it is
damaged.

3.

This failure may be caused by a dirty cartridge.
Look for any contamination on the sides of the
cartridge that could cause the pinch rollers to slip.
Clean or replace the cartridge if necessary.
Note:

Do not ship magazines with cartridges

loaded. The cartridges will vibrate in the magazine
slots resulting in contamination on the sides of the
cartridges that may cause this failure.

4.

This failure may be caused by a magazine. Try
another magazine.

5.

Call for service if problem remains.

B0, B1

Drive Problem

Call for service

B3, B4

Cartridge or Drive

Problem

1.

This failure may be caused by a damaged cartridge.
Inspect the cartridge that was being used when the
error occurred for physical defects. Replace the
cartridge if it is damaged.

2.

Call for service if problem remains.

B7

Drive Problem

Call for service

B9, BA, BB, BC

Cartridge or Drive

Problem

1.

This failure may be caused by a damaged cartridge.
Inspect the cartridge that was being used when the
error occurred for physical defects. Replace the
cartridge if it is damaged.

2.

Call for service if problem remains.

102

3590 Operator Guide

Advertising