Chapter 6. Identifying Subsystem Problems

This chapter identifies some of the problems that can occur with the
Subsystem.

Unable to Insert a Tape Cartridge

If you cannot insert a tape cartridge in the drive, perform the following steps:

1.

Inspect the tape cartridge for damage. See “Damaged Cartridges” on
page 87.

2.

Try to load another cartridge in the tape subsystem.
If the new cartridge can be inserted in the drive, the original cartridge
may be defective. Inspect the cartridge for damage.
If the cartridge is not damaged but it cannot be inserted, call your service
representative.

FID or ATTN on the Message Display

If an error code appears on the message display, record all codes that are
displayed for future reference.

FID message

See “Appendix B. FID Messages” on page 101 for operator action.

ATTN

See “FID and ATTN Supplemental Messages” on page 23.

If there is a problem on the ACF, perform the recovery action for the ACF
before you attempt any recovery action on the drive. (The ATTN ACF
indicator on the operator panel is flashing or all LEDs are flashing.) Go to
“ACF Recovery Procedure” on page 77 and perform those procedures.

Tape Drive is Not Ready

If the tape subsystem is not ready at load point, perform the following steps:

1.

If the cartridge is not inserted correctly, remove the cartridge and insert it
again. If the cartridge fails to load in the tape subsystem, remove the
cartridge and inspect it for correct type or damage. See “Chapter 7. 3590
High Performance Cartridge Tape and Extended High Performance
Cartridge Tape” on page 79
and “Damaged Cartridges” on page 87.

2.

If a FID or ATTN message appears on the message display, record the
code, select Unload, and try the operation again.