E-13, Connecting the control signal cable, Setting the switches ( ੬ page 10) – JVC TK-C1460 User Manual

Page 13: Setting on the menu screen ( ੬ page 35), A rx, B rx c tx, D tx tx

Advertising
background image

E-13

CAMERA
SETUP

SET

MENU

EXT TERM-OFF

INT/GL

DUPLEX

RX TERM-OFF

NOT USED

ON

LL

SIMPLEX

ON

EXT TERM-OFF

INT/GL

DUPLEX

RX TERM-OFF

NOT USED

ON

LL

SIMPLEX

ON

VIDEO

DC

IRIS

AWC

A RX

+

B RX
C TX

+

D TX

TX

+

A

TX

B

RX

+

C

RX

D

TX

+

A

TX

B

RX

+

C

RX

D

RM-P2580

Camera 2
control signal
connection terminals

Connect:
Camera TX+ to RM-P2580 RX+
Camera TX– to RM-P2580 RX–
Camera RX+ to RM-P2580 TX+
Camera RX– to RM-P2580 TX–
The A B C D marks indicated on both the
camera terminals and the RM-P2580 termi-
nals facilitate correct connections. Connect
the terminals with identical marks.

Connecting the control signal cable

(Use a twisted-pair cable for connection.

੬ Page 17.)

Camera 1
control signal
connection terminals

Setting the switches (Page 10)

Select the synchronization method of the
camera image.
Set the switch on all cameras to LL (Line Lock)
and match with the V. PHASE.
(

੬ Page 26.)

Set this switch to the DUPLEX
* If the setting is changed, be absolutely sure to

switch on the power again.

Set this switch to ON (signal termination ON)
only on the camera placed at the end of the
control signal cable.
Set to OFF on all other cameras.

Setting on the MENU screen (Page 35)

* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.

MACHINE ID setting switches
Set this item to match the RM-P2580 VIDEO
INPUT terminal number for each camera.

When connecting

● Turn OFF the power supply to all equipment to be used before making connections.

● Carefully read the Instructions for each piece of equipment to be used before making

connections.

● For the appropriate connection cables and the length of these, carefully read “Connections

on the back” on page 16.

● The control signal cable cannot be used for loop connection.

Set to M.DROP
Set to M.DROP when the RM-P2580 is used as
a remote control unit. When controlling from
another machine, make sure that it matches the
communication system used.

MM

C O

UN I C A T I O N

S T L E

M . DROP

Y

MA H NE

D

I

I

1

C

Advertising