Motion detect screen, Menu setting, E-34 – JVC TK-C1460 User Manual

Page 34

Advertising
background image

E-34

MENU SETTING

MOTION DETECT Screen

Item

Functions and set values

Initial value

MODE

Settings are executed about the motion detecting function that emits alarm signals when
there exists any motion in the image. Alarm signals are output from the auxiliary terminals on
the back.

This sets ON/OFF of motion detecting function.
OFF:

Motion detecting function does not work.

ON:

Motion detecting function works.

OFF

LEVEL

AREA EDIT

ALARM TIME

DEMONSTRA-
TION

This sets the level that detects motion.
If the item MODE is set to OFF, “- - -” will appear, and
settings cannot be changed.
To function with large signal level change…decrease the
value
To function with small signal level change…increase the
value
[Set values: –5 to NORMAL to 5]

This sets the range in which the motion detecting function
works.
(

੬ Page 39)

This sets the output time of the alarm signal output of
AUX terminal as well as “ALARM” display on the screen
when motion is detected.
If the item MODE is set to OFF, “- - -” will appear, and
settings cannot be changed.
[Set values: OFF, 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s,
1min]

MEMO

Even when the ALARM TIME item is set to OFF, an alarm
signal is output from the AUX terminal for about 500ms,
and “ALARM” is not displayed on the screen.

This is used when checking and confirming the set motion
detecting function. The detection area is shown in gray.
(

੬ Page 39)

NORMAL

10s

Advertising