Vent terminal clearances – Jotul GF3 DVII User Manual

Page 13

Advertising
background image

Figure 11. Vent Terminal / Overhang Clearances

Vent Terminal Clearances

Figure 10. Vent Terminal Clearances - National Fuel Gas Code.

A = Clearance above grade, veranda, porch , deck, or

balcony : *12 inches (30 cm) minimum.

B = Clearance to window or door that may be opened:

9 inches (23 cm) minimum. 12 inches is recom-
mended to help prevent condensation.

C = Recommended clearance to permanently closed

window: mimimum 12 inches (30 cm) to help
prevent condensation on the window.

D = Vertical clearance to ventilated soffit located above

the terminal within a horizontal distance of 2 feet (60
cm) from the centerline of the terminal: 18 inches
(46 cm) minimum.

E = Clearance to unventilated soffit: 12 inches (46 cm)

minimum.

F = Clearance to outside corner: 9 inches (23 cm) min.

Jøtul N.A. strongly recommends 12 inches (30 cm),
particularly where windy conditions are prevalent.

G = Clearance to inside corner: 6 inches (16 cm) min.

Jøtul N.A. strongly recommends 12 inches (30 cm), particularly
where windy conditions are prevalent.

H = *Not to be installed above a meter/regulator assembly

within 3 feet (90 cm) horizontally from the center-line
of the regulator.

I = Clearance to service regulator vent outlet: 6 feet (1.8

m) minimum.

J = Clearance to nonmechanical air supply inlet to building

or the combustion air inlet to any other appliance:
*12 inches (30 cm) minimum.

K = Clearance to a mechanical air supply inlet: *6 feet

(1.8 m) minimum.

L = ** Clearance above paved sidewalk or a paved driveway

located on public property: *7 feet (2.1 m) min.

M = Clearance under veranda, porch, deck, or balcony:

*12 inches (30 cm) minimum.

1

* As specified in CGA B149 Installation Codes. Note: Local Codes

and Regulations may require different clearances.

** A vent shall not terminate directly above a sidewalk or

driveway which is located between two single family dwellings

and serves both dwellings.*

1

Only permitted if veranda, porch, deck, or balcony, is fully open

on a minimum of two sides beneath the floor.*

76 mm

12 ”

305

mm

2 1/2”

64 mm

11

Advertising