Jotul GF3 DVII User Manual

Page 3

Advertising
background image

PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM

AVAILABLE TO ANYONE USING OR SERVICING THE APPLIANCE.

KEEP THESE INSTRUCTIONS FOR FUTURE USE.

SUGGESTED TOOL LIST FOR INSTALLATION
AND SERVICE:

• External regulator (for LPG only)
• Piping which complies with local code
• Manual shutoff valve
• Sediment trap
• Tee Handle Gas Cock - required for Massachusetts
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution

Standards............................................3
General Information ........................3
Safety Information ...........................4
Location ...............................................4
Hearth Requirements...................... 4
Stove Clearances...............................5
Mantel and Trim ...............................5
Venting Requirements ....................6
Vertical Venting ................................6
Horizontal Venting ...........................7
Co-linear Hearthmount .................. 8
Mobile Home Installation .............. 9
Vent Window .................................. 10
Vent Terminal Clearances ........... 11
Fuel Conversion .............................. 12
Gas Connection .............................. 14
Gas Pressures.................................. 14
High Altitude Adjustment .......... 15
Air Shutter Settings ...................... 16
Log Set Installation ....................... 16
Blower Installation ........................ 17
Remote Control / Thermostat .... 18
System Check ................................. 19
Operation Instructions ................ 20
Maintenance................................... 20
Illustrated Parts List ............... 22, 23

Table of Contents

Jøtul GF3 DVII Allagash

Direct Vent Gas Heater

Manufactured and Distributed by:

Jøtul A.S.A.

Fredrikstad, Norway

Jøtul North America

Portland, Maine

Test Standards

This appliance complies with
National Safety standards and is
tested and listed by Intertek
Testing Services of Middleton,
Wisconsin to ANSI Z21.88-1998
(NFPA 54) and CSA 2.33-M98 for Canada.

US

Warnock Hersey

C

THIS STOVE IS CONFIGURED TO BURN NATURAL

GAS ONLY. IF USE WITH PROPANE GAS IS DESIRED,

THE BURNER MUST FIRST BE CONVERTED. FOR

YOUR CONVENIENCE, A PROPANE CONVERSION

KIT IS INCLUDED WITH THE STOVE.

1

THIS PRODUCT MUST BE INSTALLED BY A

LICENSED MASTER OR JOURNEYMAN PLUMBER

OR GAS-FITTER WHEN INSTALLED IN THE

COMMONWEALTH OF MASSACHUSETTS.

Advertising