The Jøtul GF3 DVII Allagash is a Direct Vent wall

furnace and is designed as a sealed combustion, air
circulating gas appliance for residential applications.
The following vent components are approved for use
with the Jøtul GF3 DVII, vented directly to the
outside of the house:
• Simpson Dura-Vent 6 5/8" X 4" GS pipe
• Security Direct Vent 6/4 vent pipe
• Amerivent 6/4 vent pipe.

The Jøtul GF3 DVII Allagash gas stove is designed

to operate on NATURAL GAS or PROPANE only. It
manufactured and shipped prepared to burn Natural
Gas. For safe and efficient operation the stove is
equipped with a millivolt gas control valve with a
piezo ignitor. Electrical power is only required when
operating the OPTIONAL forced air blower.

Rear Exit

Centerline

24 3/4”

629 mm

13 1/4”

337 mm

Top Exit

27 3/4”

705 mm

28”

711 mm

22 3/4”

578 mm

2

Specifications

Input Rates

Natural Gas

26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input

Propane

26,000 BTU/hr. maximum input
20,000 BTU/hr. minimum input

Minimum Inlet Pressure:

Natural Gas:

5.0 WC (1.25 kPa)

Propane:

11.0 WC (2.75 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

2.0 WC (.85 kPa)

3.5 WC (.85 kPa)

Propane:

6.4 WC (1.60 kPa) 10.0 WC (2.50 kPa)

Steady State Efficiency: 82%
A.F.U.E.: 73%
Piezo Ignitor / Standing Pilot