John Deere POWERTECH 4045 User Manual

Page 149

Advertising
background image

Lubrication & Maintenance/500 Hour/12 Month

OURGP11,000014F

–19–27JUL06–2/2

RG12426

–UN–20NOV03

Closed Crankcase Vent

RG12427

–UN–03FEB04

Closed Crankcase Vent

A—Closed Crankcase Ventilation (CCV) Valve
B—Hose, CCV Valve to Intake Manifold
C—Hose, Valve Cover to CCV Valve
D—Valve Cover Vent Fitting
E—Intake Manifold Fitting
F—Cap Screw, CCV Valve to Bracket
G—Oil Drain Hose
H—Check Valve
I—Crankcase Oil Drain Tube

Closed Crankcase Ventilation System (If Equipped)

1. Inspect hoses (C, D and G) for kinks, blockage, or

other damage.

2. Inspect check valve (H) for damage. (Valve is installed

with black end toward crankcase).

3. Verify that crankcase oil drain tube (I) is not plugged.

4. Inspect CCV valve (A) for cracks or other damage.

30-10

080706

PN=147