Engine Operation- 4.5 L “270” Engines

OURGP11,0000134

–19–27JUL06–1/2

Stopping the Engine

RG6574B

–UN–07JAN03

Key Switch on Instrument Panel (Earlier Engines)

RG13362

–UN–06FEB04

Key Switch on Instrument Panel (Later Engines)

IMPORTANT: Stopping the engine immediately when

it has been working under load, can
result in overheating and accelerated
wear of the engine components.
ALWAYS run the engine at slow idle
and no load to allow hot engine parts to
cool before shutdown (if possible).

On engines with variable speed
governors, remove load from engine
and run engine for at least 2 minutes
Run turbocharged engines for 3 to 5
minutes.

On generator set engines with
governors locked at a specific speed,
remove electrical load from engine (if
possible) and run at fast idle and no
load for at least 2 minutes.

1. Reduce engine speed to slow idle (variable speed

governors only).

2. Turn key switch (A) to "OFF" position to stop the

engine. After engine stops, close valve on fuel supply
to prevent accidental starting.

OURGP11,0000134

–19–27JUL06–2/2

RG10616

–UN–16JUN00

Exhaust Stack Rain Cap

IMPORTANT: Make sure that exhaust stack cap (rain

cap) is in place when engine is not
running. This will prevent water and dirt
from entering engine.

3. Fill fuel tank to minimize possible water condensation

problems. Filling tanks at end of day drives out
moisture-laden air.