Lubrication and maintenance – John Deere POWERTECH 4045 User Manual

Page 131

Advertising
background image

Lubrication and Maintenance

OURGP11,000007E

–19–27JUL06–1/2

Lubrication and Maintenance Service Interval
Chart—Standard Industrial Engines

NOTE: The service intervals below are for standard

industrial engines. See details in Sections which
follow these charts.

Lubrication and Maintenance Service Intervals

500 Hour/

2000 Hour/

Item

Daily

12 Month

24 Month

As Required

Check Engine Oil and Coolant Level

•

Check Fuel Filter/Water Bowl

•

Check Air Cleaner Dust Unloader Valve & Restriction Indicator

•

Gauge

a

Visual Walk Around Inspection

•

Check Lamps (4045DF/TF270)

•

Service Fire Extinguisher

•

Check Engine Mounts

•

Service Battery

•

Check Manual Belt Tensioner and Belt Wear

•

Change Engine Oil And Replace Oil Filter

b, c

•

Check Crankcase Vent System

•

Check Air Intake Hoses, Connections, & System

•

Replace Fuel Filter Elements

•

Check Automatic Belt Tensioner and Belt Wear

•

Check Engine Electrical Ground Connection

•

Check Cooling System

•

Coolant Solution Analysis-Add SCAs as required

•

Pressure Test Cooling System

•

Check Engine Speeds

•

Check Crankshaft Vibration Damper

(6.8 L Engines)

d

•

Flush and Refill Cooling System

e

•

Test Thermostats

•

Check and Adjust Engine Valve Clearance

•

a

Replace primary air cleaner element when restriction indicator shows a vacuum of 625 mm (25 in.) H2O.

b

During engine break-in, change the oil and filter for the first time before 100 hours of operation.

c

If the recommended engine oils, John Deere PLUS-50

or ACEA-E7, ACEA E6, ACEA E5 or ACEA E4, are not used, the oil and filter

change interval is reduced (see DIESEL ENGINE OIL AND FILTER INTERVALS chart). If diesel fuel with a sulfur content greater than 0.05%
is used, the oil and filter change interval is also reduced. 6-Cylinder engines with oil pan option codes 1907, 1908, and 1909 require the oil to
be changed at every 250 hours or less regardless of oil specification used.

d

Replace crankshaft damper every 4500 hours or 60 months, whichever occurs first.

e

If John Deere COOL-GARD is used, the flushing interval may be extended to 3000 hours or 36 months. If John Deere COOL-GARD is used

and the coolant is tested annually AND additives are replenished as needed by adding a supplemental coolant additive, the flushing interval
may be extended to 5000 hours or 60 months, whichever occurs first.

21-2

080706

PN=129

Continued on next page

Advertising
This manual is related to the following products: