John Deere POWERTECH 4045 User Manual

Page 167

Advertising
background image

Lubrication & Maint./2000 Hour/24 Month

DPSG,RG34710,112

–19–27JUL06–3/5

RG5971

–UN–23NOV97

Testing Thermostat Opening Temperature

Testing Thermostats Opening Temperature

1. Remove thermostat(s).

2. Visually inspect thermostat(s) for corrosion or damage.

If dual thermostats, replace as a matched set as
necessary.

CAUTION: DO NOT allow thermostat or
thermometer to rest against the side or bottom
of container when heating water. Either may
rupture if overheated.

3. Suspend thermostat and a thermometer in a container

of water.

4. Stir the water as it heats. Observe opening action of

thermostat and compare temperatures with the
specification given in chart below.

NOTE: Due to varying tolerances of different suppliers,

initial opening and full open temperatures may
vary slightly from specified temperatures.

THERMOSTAT TEST SPECIFICATIONS

Rating

Initial Opening (Range)

Full Open
(Nominal)

71

°

C (160

°

F)

69—72

°

C (156—162

°

F)

84

°

C (182

°

F)

77

°

C (170

°

F)

74—78

°

C (166—172

°

F)

89

°

C (192

°

F)

82

°

C (180

°

F)

80—84

°

C (175—182

°

F)

94

°

C (202

°

F)

89

°

C (192

°

F)

86—90

°

C (187—194

°

F)

101

°

C (214

°

F)

90

°

C (195

°

F)

89—93

°

C (192—199

°

F)

103

°

C (218

°

F)

92

°

C (197

°

F)

89—93

°

C (193—200

°

F)

105

°

C (221

°

F)

96

°

C (205

°

F)

94—97

°

C (201—207

°

F)

100

°

C (213

°

F)

99

°

C (210

°

F)

96—100

°

C (205—212

°

F)

111

°

C (232

°

F)

5. Remove thermostat and observe its closing action as it

cools. In ambient air the thermostat should close
completely. Closing action should be smooth and slow.

6. Replace any defective thermostat. On a dual

thermostat engine, replace both thermostats.

Continued on next page

35-7

080706

PN=165

Advertising
This manual is related to the following products: