Replacing radial seal air cleaner filter element – John Deere POWERTECH 4045 User Manual

Page 183

Advertising
background image

Service as Required

RG41165,000008B

–19–27JUL06–1/2

Replacing Radial Seal Air Cleaner Filter
Element

RG11321A

–UN–08SEP00

Dust Cup/Cover

RG11322A

–UN–08SEP00

Primary Filter Element

RG11327A

–UN–08SEP00

Secondary Filter Element

A—Dust Cap/Cover
B—Primary Filter Element
C—Secondary Filter Element

IMPORTANT: ALWAYS REPLACE primary air cleaner

element when air restriction indicator
shows a vacuum of 625 mm (25 in.)
H

2

O, is torn, or visibly dirty.

NOTE: This procedure applies to John Deere 2-stage

radial seal air cleaner kits. Refer to manufacturers’
instructions for servicing air cleaners not supplied
by John Deere.

1. Unlatch and remove dust cup/cover (A) of air cleaner.

2. Move end of filter (B) back and forth gently to break

seal.

3. Pull filter (B) off outlet tube and out of housing.

4. Thoroughly clean all dirt from inside housing and from

outlet bore.

IMPORTANT: Remove secondary (safety) element (C)

ONLY for replacement. DO NOT attempt
to clean, wash, or reuse secondary
element. Replacement of secondary
element is usually necessary ONLY
when primary element has a hole in it.

5. To replace secondary element (C), pull filter element

out gently. Immediately replace secondary element
with new element to prevent dust from entering air
intake system.

6. Install new primary filter element. Apply pressure by

hand at outer rim of filter.

IMPORTANT: Do NOT use latches on cover to force

filter into air cleaner. Using cover to
force filter will damage cleaner housing.

7. Close housing with dust unloader valve aimed down

and latch latches.

40-8

080706

PN=181