Troubleshooting

OURGP11,0000087

–19–27JUL06–2/2

SPN

FMI

Blink Code

Description of Fault

04

22

Sensor Supply Voltage Low

000627

04

76

ECU Unswitched Power Missing

000629

13

34

ECU Error

19

34

ECU to Pump Communication Error

000632

02

37

Fuel Shutoff Error

05

86

Fuel Shutoff Non-Functional

000636

02

44

Pump Position Input Noise

08

43

Pump Position Input Missing

10

44

Pump Position Input Pattern Error

000637

02

39

Crank Position Input Noise

08

38

Crank Position Input Missing

10

39

Crank Position Input Pattern Error

000729

03

Inlet Air Heater Signal High

05

Inlet Air Heater Signal Low

000810

02

92

Calculated Vehicle Speed Input Noise

000898

09

77

Vehicle Speed Invalid/Missing

000970

02

Auxiliary Engine Shutdown Switch Signal Invalid

31

83

Auxiliary Engine Shutdown Switch Active

000971

31

84

External Engine Derate Switch Active

001069

02

93

Tire Size Error

001076

02

66

Pump Detected Defect

001077

07

35

Attempting to Fuel Without Command

11

68

Pump Supply Voltage Out of Range

12

97

Pump Self Test Error

19

96

Pump Detected Communication Error

31

36

Pump Initiated Engine Protection

001078

07

95

ECU/Pump Timing Moderately Out of Sync

11

87

ECU/Pump Speed Out of Sync

31

94

ECU/Pump Timing Extremely Out of Sync

001079

03

21

Sensor Supply 1 Voltage High

04

22

Sensor Supply 1 Voltage Low

001080

03

51

Sensor Supply 2 Voltage High

04

52

Sensor Supply 2 Voltage Low

001109

31

Engine Shutdown Warning

001110

31

82

Engine Shutdown

001485

02

89

Pump Power Relay Fault

001569

31

47

Fuel Derate

002000

13

Security Violation

45-25