Conversion from natural gas to lpg, Minimum flow of valved cooking hob taps, Minimum flow of non-valved cooking hob taps – John Lewis JLRC101 User Manual

Page 11: Connecting to lpg, General injectors table

Advertising
background image

11

Conversion from Natural Gas to LPG

If the cooking appliance is set up for a different type of gas
than that available, its injectors must be replaced, the
minimum flow regulated. In order to replace the injectors
in the cooking hob, it is necessary to carry out the
following operations:

• remove the pan supports;
• remove the burners and burner caps (Fig. A);
• take out the injector (Fig. B) and replace it with one

suitable for the new type of gas (see "General injectors
table");

• replace the gas label (on the rear of the appliance) with

the new one provided with the injectors kit;

• refit all parts by following the disassembly instructions in

reverse order and taking care to position the burner cap
correctly on the burner.

Minimum flow of valved cooking
hob taps

• Switch on the burner and turn the control knob towards

the minimum flow position ;

• remove the knob;
• using a screwdriver, adjust the internal screw Z until the

correct low flame is obtained;

• refit the knob.

Minimum flow of non-valved
cooking hob taps

• Switch on the burner and turn the control knob towards

the minimum flow position ;

• remove the knob;
• insert a small screwdriver into the rod of the tap and

adjust the internal screw Z until the correct low flame is
obtained;

• refit the knob.

Unscrew the adjustment screw Z to increase
the flow, or tighten it to reduce the flow. The
adjustment is correct when the low flame
measures approximately 3 or 4 mm. When
changing quickly from maximum to
minimum flow and vice versa make sure that
the flame does not go out.

Connecting to LPG

Use a pressure regulator and connect to the cylinder in
compliance with the guidelines set out in standards
regulations in force.

L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.

Fig. A

Fig. B

=

=

General injectors table

TYPE OF GAS

mBar

INJECTOR NO.

BURNERS

POSITION TYPE

POWER Watts

MAX.

CONSUMPTION

INJECTOR

BY-PASS

MAX.

MIN.

115

44 GAP

RAPID

3000

750

286 l/h

NATURAL

97

34 GAP

SEMI-RAPID

1750

440

167 l/h

GAS

20

72

27 GAP

SIMMER

1000

300

95 l/h

G20 (E)

128

60 GAP

TRIPLE RING (A)*

3300

1500

314 l/h

128

60 GAP

TRIPLE RING (D)*

3300

1500

314 l/h

LPG

85

44 GAP

RAPID

3000

750

219 g/h

BUTANE

65

34 GAP

SEMI-RAPID

1750

440

128 g/h

PROPANE

28-30/37

50

27 GAP

SIMMER

1000

300

73 g/h

G30/G31

93

60 GAP

TRIPLE RING (A)*

3300

1500

240 g/h

93

60 GAP

TRIPLE RING (D)*

3300

1500

240 g/h

* Position A: front left, position D: centre rear (see also "Description of the cooktop").

Advertising