JVC TK-C655 User Manual

Page 11

Advertising
background image

11

VIDEO
SWITCHER, etc.

CONTROLLER*

Length of stub

Length of stub

CONTROL Cable

CAM1

CAM2

CAM31

CAM32

PROTOCOL(1) : ON
MACHINE ID

: 01

RX TERM

: ON

PROTOCOL(1) : ON
MACHINE ID

: 02

RX TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 31

RX TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 32

RX TERM

: ON

Length of stub

VIDEO
SWITCHER, etc.

CONTROLLER*

Length of stub

CONTROL Cable

PROTOCOL(1) : ON
MACHINE ID

: 01

RX TERM

: ON

PROTOCOL(1) : ON
MACHINE ID

: 02

RX TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 32

RX TERM

: OFF

Length of stub

CAM1

CAM2

CAM32

Terminate it
with 110

1.

• Set the TERM switches of the cameras at each end

(CAM1 and CAM32) to ON, and the TERM switches of
the other cameras to OFF.

• Do not terminate at the controller.

• Set the TERM switch of CAM1 to ON, and terminate at the con-

troller with a resistance of 110

1.

Set the TERM switches of the other cameras to OFF.

When the controller is located at the end of a system.

(An AC 24V power source must be supplied to each camera)

( CAUTION

When the controller is not located at the end of a system.

(An AC 24V power source must be supplied to each camera)

( CAUTION

Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated
equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, control precision may suffer.

MEMO

A system that does not employ the RM-P2580 as the controller

CAUTIONS

The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)

In order to prevent an excessive current flow through the power supply wire or camera due to a
short circuit, a fuse must be installed in the power supply line.

Advertising