12

Connections & Installation

Point-to-Point Communication System

The following illustration shows a system in which a remote control unit (or a similar piece of equipment) controls a single camera.

Observe the following points when connecting components together:
• Turn all the components off before proceeding.
• Read the instruction manuals of all components before proceeding.

Control signal cable

AC 24 V
power supply

(

CAUTION

Video out

Controller

Monitor

Switch 4 : OFF
(Point to Point)
Switch 8 : ON
(Terminated 110

1)

Cable connections

P. 16

(Terminal side of the Ceiling Mount)

Power cable

Control signal cable

To the AC 24V power supply

(

CAUTION

To controller

Coaxial cable

To monitor

If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms
of magnetism, for example near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from
noise and colors may be affected.
An optionally available controller is required to use a TK-C655 or TK-C676 camera. Please contact your local dealer or installer
for more information about these controllers.

MEMO

Switch settings

P. 14

(Setting switches are on the side of the Ceiling Mount)

Setting not
required

1

2

3

4

6

7

8

5

O

F

F

Setting not
required

Switch 1 :
Switch 2 :
Switch 4 : OFF

Switch 5 :

Configure in accordance

with the requirements of the controller
communication system.

Switch 7 : Invalid (Set to OFF)
Switch 8 : ON

Invalid (Set to OFF)

CAUTIONS

The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)

In order to prevent an excessive current flow through the power supply wire or camera due to a short circuit, a fuse must be installed in the
power supply line.