Setting manually, Setting electronically – John Lewis JLBIDW 1201 User Manual

Page 11

Advertising
background image

Water hardness

Adjustment of the water

softener

Use of salt

Clarke

°TH

mmol/l

manually

electronically

64 - 88

91 - 125

9.1 - 12.5

2

level 10

yes

53 - 63

76 - 90

7.6 - 8.9

2

level 9

yes

46 - 52

65 - 75

6.5 - 7.5

2

level 8

yes

36 - 45

51 - 64

5.1 - 6.4

2

level 7

yes

28 - 35

40 - 50

4.0 - 5.0

2

level 6

yes

23 - 27

33 - 39

3.3 - 3.9

2

level 5

yes

18 - 22

26 - 32

2.6 - 3.2

1

level 4

yes

13 - 17

19 - 25

1.9 - 2.5

1

level 3

yes

5 - 12

7 - 18

0.7 - 1.8

1

level 2

yes

< 5

< 7

< 0.7

1

level 1

no

The water softener must be set in
two ways, manually and
electronically.

Setting manually

The appliance is factory set at position 2.
1. Open the appliance door.
2. Remove the lower basket from the

appliance.

3. Turn the water hardness dial to position

1 or 2. Refer to the water hardness
table.

4. Replace the lower basket.

Setting electronically

The appliance is factory set at level 5.
1. Switch on the appliance. Make sure that

the appliance is in setting mode.

2. Press and hold the Start/Cancel button

until the programme indicator (A) starts
to flash and the programme indicator
(B) comes on.

3. When the programme indicator (B)

goes off and the End indicator starts to
flash, press the Start/Cancel button. The
programme indicator (A) starts to flash,
the electronic adjustment of the water
softener is now activated.

4. The number of flashes of the End

indicator indicates the current setting of
the water softener (e.g. 5 flashes of the
End indicator / pause / 5 flashes of the
End indicator = level 5 )

5. To change the level, press the Start/

Cancel button. Each time the button is
pressed the level increases. Refer to the
water hardness table.

11