Item

“IRIS MODE”

“MANUAL
LEVEL”

“GAIN”

“LEVEL”

“SHUTTER”

“EXPOSURE” Screen

Function/Variable Values

Switch according to the lens in use.
“AUTO”

: When using auto iris lens.

“MANUAL”

: When using manual iris lens.

For setting the iris level when “IRIS MODE” is set to “MANUAL”. (Set the iris mode
switch on the lens side to “AUTO”.)
Increase value

: Opens the iris.

Decrease value : Closes iris.
{Variable Values : 0 - 128 - 255}
Note
When “IRIS MODE” is set to “AUTO”, “MANUAL LEVEL” item selection will be
disabled. (Displayed as “- - - - - -”)
For switching the electric sensitivity mode.
“STEP”

: Gain boost level can be altered using the “LEVEL” item.

“V. GAIN”

: Gain boost level can be fine-tuned using the ”LEVEL“ item.

“ALC”

: Alters gain boost level automatically according to the

brightness.
Set the maximum value at the “ALC LIMIT” item.

☞ Page 35

Gain boost level can be altered when gain boost mode is set as “STEP” or “V.
GAIN”.
{Variable “STEP” Values: –3, 0, +3, +6, +9, +12, +15, +18dB, LOLUX}
{Variable “V. GAIN” Values: –3 - 0 - 18dB 0.2dB Step}
Note
When “GAIN” is set to “ALC”, “LEVEL” item selection will be disabled.
(Displayed as “- - - - - -”)
For switching the shutter mode.
“STEP”

: Shutter speed can be altered using the “LEVEL” item.

“V. SCAN”

: Align scan speed of monitor to eliminate horizontal lines that

appear when shooting the computer monitor. Shutter can be
fine-tuned using the “LEVEL” item.
☞ Page 26 ‘Shooting the Computer Monitor’