System specifications, Appendix a, Appendix a, system specifications – Juniper Networks ERX-1410 User Manual

Page 119: Ls of heat. see, Appendix a, system, Specifications, Specifications (see

Advertising
background image

A

System Specifications

Table A-1 ERX specifications

ERX-1400 Series

ERX-700 Series

Weight
Chassis only
Chassis fully configured

42 lb (18.9 kg)
88 lb (39.6 kg)

22 lb (9.9 kg)
46 lb (20.7 kg)

Dimensions

22.75 (H) x 19 (W) x 16 (D) inches
(57.78 x 48.26 x 40.64 cm)

10.5 (H) x 19 (W) x 16 (D) inches
(26.67 x 48.26 x 40.64 cm)

Environmental Requirements
Ambient operating temperature

Ambient operating humidity

Ambient storage temperature
Ambient storage humidity

(NEBS GR-63-CORE compliant)
Long term: 41

°

to 104

°

F (5

°

to 40

°

C)

Short term: 23

°

to 122

°

F (-5

°

to 50

°

C)

Long term: 5% to 85% (noncondensing)
Short term: 5% to 95% (noncondensing)
–40

°

to 158

°

F (–40

°

to +70

°

C), 95% relative humidity

5% to 95% (noncondensing)

Heat Dissipation

2400 W, 8190 BTU/hour maximum

1400 W, 4780 BTU/hour maximum

Space Requirements

•

3 feet (90 cm) behind system or
rack

•

No space requirements for sides of
units or rack

•

Do not block air vents on front or
back of the system.

•

3 feet (90 cm) behind system or
rack

•

Do not block air vents on sides of
the system.

•

Do not place equipment that
exhausts hot air to right of the
system.

•

Be aware that system exhausts hot
air from its left side.

•

Allow at least 18 inches (45 cm) at
side of the unit or rack.

Advertising