Cabling Recommendations

ERX Edge Routers

D-7

Cabling Recommendations

You may want to consult the document

GR-63 (LSSGR, FD-15): Network

Equipment Building System (NEBS) Requirements: Physical Protection,
Issue 1, October 1995

for additional cable recommendations.

Comply with the following recommendations:

•

Use only shielded cables.

•

Ensure that cable distance and rate limits meet IEEE-recommended
maximum speeds and distances for signaling purposes. For
information about attenuation and power loss in optical fiber cables
see:

>

ANSI T1.646a-1997: Telecommunications – Broadband ISDN -
Physical Layer Specification for User-Network Interfaces Including
DS1/ATM (1997)

>

ANSI T1.646-1995: Telecommunications – Broadband ISDN -
Physical Layer Specification for User-Network Interfaces Including
DS1/ATM (1995)

>

AT&T (Lucent) Technical Note Power Margin Analysis (November
1995)

•

Ensure that power cables deliver sufficient power to the system.

•

In accordance with

IEC 825-1, Safety of Laser Products - Part 1

, laser

fiber connectors are for connection only to Class 1 laser devices.

•

Route cables so that they do not restrict ventilation or airflow.

•

Route cables so that modules and field-replaceable units are easily
accessible.

•

Route cables in a logical direction to prevent loss of connectivity to
other equipment in the rack, associated equipment in adjacent racks,
or to the backbone network.

•

Consider using cable-management brackets to keep network cables
untangled and orderly and to prevent cables from hindering access to
other slots.

•

For specifications on cables for line modules, see

Appendix B, Module

Specifications

.