System setting screen, Menu screen settings (continued) – JVC KY-F1030U User Manual

Page 44

Advertising
background image

E40

Item

AE DISPLAY

FRZ DISPLAY

FRZ CANCEL

TEST PATTERN

LEVEL
When “BAR”/
“IMPULSE”
is selected

MENU RESET

SYSTEM SETTING screen

5. Menu screen settings (continued)

[ ] indicates the factory setting

Set Value

[OFF]

ON

[ON]

OFF

[MANUAL]
AUTO (1s)
AUTO (3s)
AUTO (5s)

OFF

[BAR]

RAMP

IMPULSE

[0.7V]
0.57V

Contents

Used to set whether the ALC, EEI and IRIS values are
displayed on the analog output screen.
OFF:

No on-screen-display

ON:

On-screen-display

Used to set whether the “FREEZE” indicator is shown on
the screen at the time of trigger input.
ON:

Displayed

OFF:

Not displayed

Sets the method for canceling the FREEZE when the
monitor screen is in FREEZE condition when connection
is made through digital output.
MANUAL : Cancelled by trigger input.
AUTO(1s) : Cancelled after 1 second.
AUTO(3s) : Cancelled after 3 seconds.
AUTO(5s) : Cancelled after 5 seconds.
OFF

: Not cancelled.

* When set to “AUTO” or “OFF”, the displayed screen can

be updated by trigger input during the FREEZE condi-
tion.

Sets the test pattern type output when the function set-
ting switch No.1 <TEST PATTERN> is set to “ON”.
BAR

: “BAR” pattern is output.

RAMP

: “RAMP” pattern is output.

IMPULSE : “IMPULSE” pattern is output.

Sets the level of the color signal bar output from the KY-
1030’s [ANALOG OUT] connector.
0.7V:

0.7V test signal is output

0.57V:

0.57V test signal is output

Resets all the set values of menus to the initial values.

page E43, Resetting menu settings