Johnson Controls Residential Gas TM9V MP User Manual

Page 12

Advertising
background image

438335-UIM-B-0509

12

Johnson Controls Unitary Products

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available on-line at www.upgnet.com in
the Product Catalog Section.

FIGURE 18: Thermostat Chart - Single Stage Air Conditioners with Two Stage Variable Speed Furnaces

AC 9A

Single Stage Air Conditioner – Two Stage Variable Speed Furnace

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

C

24 – Volt Common

R

24 – Volt Hot

Y

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22C00124

THERMOSTAT

W2

Second Stage Heat

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DP22U70124

THERMOSTAT

W2

Second Stage Heat

Step 1 of Thermostat User

Configuration Menu must

be set to MS 2

W

First Stage Heat

E/W1

First Stage Heat

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Part Number:

S1-2HU16700124

External Humidistat

(Optional)

Open on Humidity Rise

C

24 – Volt Common

Y

Compressor

Y

Compressor Contactor

SINGLE STAGE

AIR

CONDITIONER

Part Numbers:

SAP = Legacy

265904 = 031-09169
449572

1

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage

Compressor

TWO STAGE

VARIABLE SPEED

FURNACE CONTROL

G

Fan

TWO STAGE

VARIABLE SPEED

FURNACE

W/W1

First Stage Heat

Y/Y2

Second or Full

Stage Compressor

W2

Second Stage Heat

O

Reversing Valve

X/L

Malfunction Light

DHUM

Dehumidification

1

Move DHUM

jumper to “YES”

if humidistat is to be used.

PV(8/9)

ID MODELS

(F/L)*(8/9)V

(G/L)*(8/9)V

C

24 – Volt Common

Y

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*PP32U70124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Thermostat Installer Setup

0170-System Type-must

be set to 9-2 Heat/1 Cool

Multistage Conventional

C

24 – Volt Common

Y

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22U00124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

First Stage Heat

W

First Stage Heat

Connection of the “C”

terminal, 24-volt common

is optional when used with

batteries

Thermostat Installer Setup

1-System Type-must

be set to 7-2 Heat/1 Cool

Multistage Conventional

Thermostat Installer Setup
15-Compressor Protection

-must be set to 5

2

2

TM(8/9)V

Advertising