Johnson Controls Residential Gas TM9V MP User Manual

Page 13

Advertising
background image

438335-UIM-B-0509

Johnson Controls Unitary Products

13

FIGURE 19: Thermostat Chart - Single Stage Heat Pump with Two Stage Variable Speed Furnace (Hot Heat Pump or Conventional)

Part Numbers:

SAP = Legacy

265904 = 031-09169
449572

2

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage

Compressor

TWO STAGE

VARIABLE SPEED

FURNACE CONTROL

G

Fan

TWO STAGE

VARIABLE SPEED

FURNACE

W/W1

First Stage Heat

Y/Y2

Second or Full

Stage Compressor

W2

Second Stage Heat

O

Reversing Valve

X/L

Malfunction Light

DHUM

Dehumidification

2

Move HEAT PUMP

jumper to “YES”

Move DHUM

jumper to “YES”

if humidistat is to be used.

PV(8/9)

ID MODELS

(F/L)*(8/9)V

(G/L)*(8/9)V

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

G

Fan

*DP32H70124

THERMOSTAT

W1

Second Stage

Aux. Heat

E

Emergency Heat

W2

Third Stage Heat

Step 1 of Thermostat

Installer / Configuration

Menu must be set to

Heat Pump 1

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

Y2

Second Stage

Compressor

G

Fan

*BP21H50124

*BN21H00124
*DP21H40124

*DN21H00124

THERMOSTAT

E

Emergency Heat

W2

Second Stage Heat

B/O Switch on Thermostat

must be in the O position

24VAC Humidifier

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

Part Number:

S1-2HU16700124

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage

Compressor

Y1

Single Stage

Compressor

X/L

Malfunction Light

Y2

Second Stage

Compressor

W

Auxiliary Heat

BS

Bonnet Sensor

BSG

Bonnet Sensor

YORKGUARD VI

CONTROL

SINGLE STAGE

HEAT PUMP

Change FFuel jumper

on the heat pump control

to “ON”

1

H*3

YMB

YZB

OD MODELS

Part Numbers:

SAP = Legacy

126768 = 031-09137

18395 = 031-01996
340512 = 031-09178

1

Y2

Second Stage

Compressor

HP 15A Single Stage Heat Pump – Two Stage Variable Speed Furnace (Hot Heat Pump or Conventional)

Change Hot Heat Pump

jumper on the heat pump

control to “ON” if Hot Heat

Pump Operation is desired.

C

24 – Volt Common

Y

First Stage Compressor

O/B

Reversing Valve

L

Malfunction Light

G

Fan

*DN22U00124

THERMOSTAT

E

Emergency Heat

AUX

Auxiliary Heat

R

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

Thermostat Installer Setup

1-System Type-must be set

to 5 – 2 Heat/1 Heat Pump

Thermostat Installer Setup

2-Changeover Valve-must

be set to 0 – O/B terminal

Energized in Cooling

External Humidistat

(Optional)

Open on Humidity Rise

3

3

3

Bonnet Sensor Kit

(Optional)

S1-37309243000

TM(8/9)V

Advertising