Table 15: Gas Rate (CU FT/HR) at Full Input

Seconds For
1 Revolution

Size of Test Dial

Seconds For
1 Revolution

Size of Test Dial

1 Cu Ft

2 Cu Ft

5 Cu Ft

1 Cu Ft

2 Cu Ft

5 Cu Ft

10

360

720

1800

55

65

131

327

11

327

655

1636

56

64

129

321

12

300

600

1500

57

63

126

316

13

277

555

1385

58

62

124

310

14

257

514

1286

59

61

122

305

15

240

480

1200

60

60

120

300

16

225

450

1125

62

58

116

290

17

212

424

1059

64

56

112

281

18

200

400

1000

66

54

109

273

19

189

379

947

68

53

106

265

20

180

360

900

70

51

103

257

21

171

343

857

72

50

100

250

22

164

327

818

74

48

97

243

23

157

313

783

76

47

95

237

24

150

300

750

78

46

92

231

25

144

288

720

80

45

90

225

26

138

277

692

82

44

88

220

27

133

267

667

84

43

86

214

28

129

257

643

86

42

84

209

29

124

248

621

88

41

82

205

30

120

240

600

90

40

80

200

31

116

232

581

92

39

78

196

32

113

225

563

94

38

76

192

33

109

218

545

96

38

75

188

34

106

212

529

98

37

74

184

35

103

206

514

100

36

72

180

36

100

200

500

102

35

71

178

37

97

195

486

104

35

69

173

38

95

189

474

106

34

68

170

39

92

185

462

108

33

67

167

40

90

180

450

110

33

65

164

41

88

176

439

112

32

64

161

42

86

172

429

116

31

62

155

43

84

167

419

120

30

60

150

44

82

164

409

124

29

58

145

45

80

160

400

128

28

56

141

46

78

157

391

133

27

54

135

47

76

153

383

138

26

52

130

48

75

150

375

144

25

50

125

49

73

147

367

150

24

48

120

50

72

144

360

157

23

46

115

51

71

141

355

164

22

44

110

52

69

138

346

171

21

42

105

53

68

136

340

180

20

40

100

54

67

133

333

Advertising