Noise Measurement Methodology


























































JUNOSg 3.0 G10 CMTS Hardware Guide

84

Figure 23: Average Upstream Noise Measurement Example

Peak Upstream Noise Measurement

This section defines a procedure for taking the peak upstream noise measurements required
as part of the RF plant and HFC environment characterization. We recommend that you take
a sample of 10 percent of the nodes terminated at the installation site. Table 34 provides the
appropriate setup configuration settings for the HP 8591C spectrum analyzer.

Table 34: Peak Noise Spectrum Analyzer Setup

1.

Connect the spectrum analyzer to the selected upstream signal at the upstream splitter
or at the CMTS upstream port.

2.

Configure the spectrum analyzer using the values defined in Table 34.

3.

Start the measurement.

After completing the measurement, the analyzer display should resemble Figure 24 on
page 85.

Setting

Value

Start frequency

2 MHz

Stop frequency

45 MHz

Resolution bandwidth

100 kHz

Video bandwidth

30 kHz

Scale

5 dB/div

Internal amplifier

Off

Attenuator

0 dB

Reference level of headend

0 dBmV

Max Hold

1 minute