StorageTek 9840 User Manual

Page 36

Advertising
background image

Operator Panels

1-12

Sixth Edition

95741

clean

(amber)

On (steady):

Drive requires cleaning because of:

1. Distance, when a firmware defined length of
tape has passed over the R/W heads.

2. Error, after a read/write perm and at least half
the firmware defined length of tape has passed
over the R/W heads.

service

(red)

Off:

Flashing:

On (steady):

No error was detected.

An error/s detected and dump data is being
collected to the EEPROM.

If within one minute the drive detects the same
FSC, the message

DumpAgain?

is displayed: see

“DumpAgain? Indication” on page 7-12

for

instructions.

A hardware error was detected and drive is not
functional. A constant indicator cannot be
ignored by the operator. If a manually initiated
IPL doesn’t eliminate problem, the drive should
be replaced.

Table 1-3. Operator Panel Indicators (Continued)

Indicator
Name

Indication

Explanation