9.2 Choice 2: Network Configuration

Use this function to access network settings.

-----------------------------------------------------------------------------

Network settings

-----------------------------------------------------------------------------

1 : Read Network settings

2 : Modify Network settings

3 : Set Ethernet speed

0 : Exit

-----------------------------------------------------------------------------

9.2.1 Choice 1: Read Network settings

Enables reading of the card's routine settings

Network configuration :

MAC address : 00:06:23:00:1F:8F

Mode : Static IP

IP address : 172.17.18.129

Subnet mask : 255.255.248.0

Gateway : 172.17.17.1

9.2.2 Choice 2: Modify Network settings

Enables the modification of network parameters

For each of the following questions, you can press <Return> to select the value

shown in braces, or you can enter a new value.

Should this target obtain IP settings from the network?[N]

Static IP address [172.17.18.129]?

Subnet Mask IP address [255.255.248.0]?

Gateway address IP address [172.17.17.1]?

Wait during your new configuration is saved ...

Reset the card to take into account the new configuration.

In DHCP mode, the card can receive the following parameters according to the DHCP server settings

IP address

Subnet Mask

Gateway address

Primary DNS server

Secondary DNS server

The card must be

restarted in order for the new parameters to be taken into account.