Ab d – Slant/Fin Sentry S-60 to S-150 User Manual

Page 7

Advertising
background image

S-34

34,000

29,000

25,000

167

80.4

84.0

8

1

8

14

5

8

4

_

_

S-60

60,000

51,000

44,000

293

81.6

84.4

11

1

8

17

5

8

4

_

_

S-90

90,000

76,000

66,000

440

82.3

84.2

14

1

8

20

5

8

5

_

_

S-120

120,000

101,000

88,000

587 83.0

84.1

17

1

8

23

5

8

6

_

_

S-150

150,000

125,000

109,000

727

82.4

83.4

20

1

8

26

5

8

7

_

_

SX-150

150,000

126,000

110,000

733

82.1

83.2

20

1

8

26

5

8

_

6

47

SX-180

180,000

151,000

131,000

873

82.1

83.1

23

1

8

29

5

8

_

7

48

3

16

SX-210

210,000

175,000

152,000

1013

82.0

83.1

26

1

8

32

5

8

_

7

48

3

16

MODEL

NUMBER †

A.G.A.
INPUT

(Btuh)

D.O.E.

CAPACITY

(Btuh)

NET

I=B=R

RATING

WATER
(Btuh) *

WATER

(Sq.Ft.)

STANDING

PILOT

INTERMITTENT

IGNITION

RATINGS FOR SENTRY BOILERS--NATURAL AND L.P. GAS

EFFICIENCY

(A.F.U.E.%)

DIMENSIONS-Inches

A

B

D

C-

VENT DIAMETER

* Net ratings are based on a piping and pick-up allowance of 1.15. Slant/Fin
should be consulted before selecting a boiler for installation having unusual
piping and pick-up requirements. Ratings must be reduced by 4% at 2,000
feet elevation and an additional 4% for every additional 1,000 feet elevation
over 2,000 feet.

†Type of gas: after model number, specify gas by name “Natural” or
“Propane”.
Note: All Sentry boilers are tested and rated for capacity under the U.S.

Dept. of Energy (D.O.E.) Test Procedure for boilers.

C

19

3

/

4

"

19

3

/

4

"

19

3

/

4

"

1

1

/

2

"

Supply

1

1

/

2

"

Supply

1

1

/

2

"

Supply

3

/

4

"

Drain

3

/

4

"

Drain

3

/

4

"

Drain

3

/

4"

to air eliminating

system (by others)

3

/

4"

to air eliminating

system (by others)

3

/

4"

to air eliminating

system (by others)

Rollout Safety

Switch

(behind

front panel)

Rollout Safety

Switch

(behind

front panel)

Rollout Safety

Switch

(behind

front panel)

Vent Damper*

Vent Damper*

Vent Damper*

Vent Damper*

28

7

/

16

"

28

7

/

16

"

32

7

/

16

"

6

1

/

2

"

Pressure/Temp.

Gauge

Pressure/Temp.

Gauge

High Limit.

Control

Ignition
Control

High Limit

Control

Ignition
Control

High Limit

Control

Ignition
Control

Blocked Vent

Safety Switch

Blocked Vent

Safety Switch

Blocked Vent

Safety Switch

Supply Piping

(by others)

Supply Piping

(by others)

Combination

Gas Valve

(gas tapping 1/2")

Combination

Gas Valve

(gas tapping 1/2")

Combination

Gas Valve

(gas tapping 1/2")

Ground

Joint Union

Ground

Joint Union

Ground

Joint Union

Circulator:

1/4" Circ. Flange

1

1

/

2" Return Tapping

Circulator:

1/4" Circ. Flange

1

1

/

2" Return Tapping

Circulator:

1/4" Circ. Flange

1

1

/

2" Return Tapping

Sediment Trap

(required)

Sediment Trap

(required)

Sediment Trap

(required)

(Dotted piping

by others.)

(Dotted piping

by others.)

(Dotted piping

by others.)

Integral

Draft

Diverter

Pressure/Temp.

Gauge

C

A

B

C

A

A

B

B

C

D

INTEGRAL

DRAFT

DIVERTER

EXTERNAL

DRAFT

HOOD

Dimensions
MODELS S-60
to S-150

Dimensions
MODEL S-34

Dimensions
MODELS SX-150
to SX-210

LEFT END VIEW FRONT VIEW RIGHT END VIEW

LEFT END VIEW FRONT VIEW RIGHT END VIEW

LEFT END VIEW FRONT VIEW RIGHT END VIEW

*Vent damper may be installed horizontally on all models with use of a common vent elbow.

Advertising
This manual is related to the following products: