Ab d – Slant/Fin Sentry S-60 to S-150 User Manual
Page 7

S-34
34,000
29,000
25,000
167
80.4
84.0
8
1
⁄
8
14
5
⁄
8
4
_
_
S-60
60,000
51,000
44,000
293
81.6
84.4
11
1
⁄
8
17
5
⁄
8
4
_
_
S-90
90,000
76,000
66,000
440
82.3
84.2
14
1
⁄
8
20
5
⁄
8
5
_
_
S-120
120,000
101,000
88,000
587 83.0
84.1
17
1
⁄
8
23
5
⁄
8
6
_
_
S-150
150,000
125,000
109,000
727
82.4
83.4
20
1
⁄
8
26
5
⁄
8
7
_
_
SX-150
150,000
126,000
110,000
733
82.1
83.2
20
1
⁄
8
26
5
⁄
8
_
6
47
SX-180
180,000
151,000
131,000
873
82.1
83.1
23
1
⁄
8
29
5
⁄
8
_
7
48
3
⁄
16
SX-210
210,000
175,000
152,000
1013
82.0
83.1
26
1
⁄
8
32
5
⁄
8
_
7
48
3
⁄
16
MODEL
NUMBER †
A.G.A.
INPUT
(Btuh)
D.O.E.
CAPACITY
(Btuh)
NET
I=B=R
RATING
WATER
(Btuh) *
WATER
(Sq.Ft.)
STANDING
PILOT
INTERMITTENT
IGNITION
RATINGS FOR SENTRY BOILERS--NATURAL AND L.P. GAS
EFFICIENCY
(A.F.U.E.%)
DIMENSIONS-Inches
A
B
D
C-
VENT DIAMETER
* Net ratings are based on a piping and pick-up allowance of 1.15. Slant/Fin
should be consulted before selecting a boiler for installation having unusual
piping and pick-up requirements. Ratings must be reduced by 4% at 2,000
feet elevation and an additional 4% for every additional 1,000 feet elevation
over 2,000 feet.
†Type of gas: after model number, specify gas by name “Natural” or
“Propane”.
Note: All Sentry boilers are tested and rated for capacity under the U.S.
Dept. of Energy (D.O.E.) Test Procedure for boilers.
C
19
3
/
4
"
19
3
/
4
"
19
3
/
4
"
1
1
/
2
"
Supply
1
1
/
2
"
Supply
1
1
/
2
"
Supply
3
/
4
"
Drain
3
/
4
"
Drain
3
/
4
"
Drain
3
/
4"
to air eliminating
system (by others)
3
/
4"
to air eliminating
system (by others)
3
/
4"
to air eliminating
system (by others)
Rollout Safety
Switch
(behind
front panel)
Rollout Safety
Switch
(behind
front panel)
Rollout Safety
Switch
(behind
front panel)
Vent Damper*
Vent Damper*
Vent Damper*
Vent Damper*
28
7
/
16
"
28
7
/
16
"
32
7
/
16
"
6
1
/
2
"
Pressure/Temp.
Gauge
Pressure/Temp.
Gauge
High Limit.
Control
Ignition
Control
High Limit
Control
Ignition
Control
High Limit
Control
Ignition
Control
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Supply Piping
(by others)
Supply Piping
(by others)
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Ground
Joint Union
Ground
Joint Union
Ground
Joint Union
Circulator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1
/
2" Return Tapping
Sediment Trap
(required)
Sediment Trap
(required)
Sediment Trap
(required)
(Dotted piping
by others.)
(Dotted piping
by others.)
(Dotted piping
by others.)
Integral
Draft
Diverter
Pressure/Temp.
Gauge
C
A
B
C
A
A
B
B
C
D
INTEGRAL
DRAFT
DIVERTER
EXTERNAL
DRAFT
HOOD
Dimensions
MODELS S-60
to S-150
Dimensions
MODEL S-34
Dimensions
MODELS SX-150
to SX-210
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
*Vent damper may be installed horizontally on all models with use of a common vent elbow.