3 rs485 setup – Speco Technologies 8TH User Manual

Page 54

Advertising
background image

User’s Manual

DVR-4TH/8TH/16TH Series
SPECO TECHNOLOGIES 07/10

53

Analog Camera

Analog Camera Select
Dome Protocol
Dome ID
Camera Title
Covert/ Privacy Mask
Termination
Brightness
Contrast
Saturation
Hue
Audio Association
Copy Settings

CH01

None

0

Ch1

On

0
0
0
0

Yes


To configure dome protocol, first select a camera then set the communication
protocol associated with that dome camera using the direction keys and press
ENTER.

NOTE: The settings only become effective after saving the changes
and exiting from the menu.

4.6.3

RS485 Setup

The DVR-4TH/ 8TH/ 16TH series unit controls the dome cameras via RS-485
communication protocol. The RS-485 parameters for the DVR-4TH/ 8TH/
16TH
series unit must be set to the same parameters set in the dome
camera.

Users are allowed to change the RS-485 settings for the DVR-4TH/ 8TH/
16TH
series unit. Select <System Setup> in the Main menu, then select
<RS485 Setup> from the System Setup menu and press ENTER. The
following menu is displayed.

RS485 Setup

Unit ID
Baud Rate
Bits
Stop
Parity

224

9600

8
1

None


The Unit ID number must match the ID address of the dome camera. The
range of the Unit ID is from 1 to 255 while the default is 224. Note that no two
devices on the same bus should be given the same ID address, or a conflict
may occur.

Advertising