Siemens CP 1515 User Manual
Page 238

,QWURGXFWLRQ
238
Industrial Ethernet Wireless LAN RLM Manager, CP 1515 Manager
C79000-G8976-C171-01
Contin.
Green
Flicker
Green
Amber
-
Network overload.
The Ethernet connection sends
more traffic to wireless stations
than the RLM Bridge can forward
to the interface
1
.
Run the RLM Manager Remote
Statistics to investigate network
performance.
If possible try to eliminate
redundant traffic by:
• Filtering protocols
• Setting storm threshold, or
• Shut down Ethernet stations
that transmit excessive data
-
Amber
Green
Amber
Amber
Contin.
Green
Flash Red -
-
Frames are rejected because of an
unknown cause.
• Run the RLM Manager Remote
Statistics to investigate the
number of packets in error.
• If this number is relatively high,
run a remote link test to
determine which station is
causing the packet loss.
-
Flash Red -
-
Flash Red
1.
When traffic load exceeds the wireless throughput capacity (>11MB/s), the RLM will buffer
such requests. In this situation however the buffer is full, and packets are ignored.