SATO M10e User Manual

Page 23

Advertising
background image

SATO M10e

PN 9001101 Rev. A

Page 3-1

SECTION 3.

CONFIGURATION

PRINTER DIP SWITCH CONFIGURATION

DIP SWITCH PANELS

There are two DIP switches (DSW2 and DSW3) located on the leftside of the printer under a
flip-up cover. Raise the Top Cover for access to these switches. In addition, a third DIP switch
is located on the RS232C Serial Adapter card and is used to set the RS232C transmit/receive
parameters. These switches can be used to set:

• Thermal transfer or direct thermal mode
• Label sensor enable/disable
• Head check mode
• Hex dump mode
• Single Job or Multi-Job Receive buffer
• Operation mode

Each switch is an eight section toggle switch. The ON position is always to the left. To set the
switches, first power the unit Off, then position the DIP switches. Finally, after placing the
switches in the desired positions, power the printer back on. The switch settings are read by
the printer electronics during the power up sequence. They will not become effective until the
power is cycled.

RS232 TRANSMIT/RECEIVE SETTING
Data Bit Selection (DSW1-1).
This switch sets the printer to receive either 7 or 8 bit data bits
for each byte transmitted.

Parity Selection (DSW1-2, DSW1-3. These switches select the type of parity used for error
detection.

DSW1-1

SETTING

Off

8 Data Bits

On

7 Data Bits

DSW1

ON

OFF

1

2

3

4

5

6

7

8

DSW1-1

DSW1-3

SETTING

Off

Off

No Parity

Off

On

Even

On

Off

Odd

On

On

Not Used

DSW1

ON

OFF

1

2

3

4

5

6

7

8

Advertising