ScyTek Electronics PRECISION PRO 5500 User Manual

Page 39

Advertising
background image

Precision Pro - Page 35

5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when

the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors

or the driver’s door only. If driver’s door only is selected, the optional Passenger Unlock wire must

be connected. (

See Two Stage Door Lock Diagrams)

6. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.

Many new import vehicles’ factory door locking systems require two pulses on the proper wire to
unlock the doors. These systems can be interfaced directly without the use of relays or any
additional circuitry by programming the system for double unlock pulse.

7. Door Lock Pulse Length. Selects between a 1, 3 or 0.1 seconds output for door locking and

unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.

8. Passive Door Locking. Selects whether or not the system will automatically lock the doors during

Passive Arming.

9. Remote Start Confirmation Chirps. When enabled, system chirps before starter is activated.

When disabled, no chirps will sound upon start.

10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a

residual dome light circuit that remains on for a period of time after closing the door.

11. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.

Momentary operation provides an output for as long as the transmitter button is pressed.(1-way

remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is

pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and

remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be

programmed to output for 1 second up to 255 seconds.

12. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 2.

Momentary operation provides an output for as long as the transmitter button is pressed.(1-way

remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is

pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and

remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be

programmed to output for 1 second up to 255 seconds.

13. Auxiliary 3 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 3.

Momentary operation provides an output for as long as the transmitter button is pressed.(1-way

remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is

pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and

remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be

programmed to output for 1 second up to 255 seconds.

Advertising