Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

9

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

NEW 2 way gas driven VRF with electrical

power generator

SANYO’s ECO G Power is a revolution in air

conditioning design. Fitted with a permanent

magnet, non-bearing type generator, it is the first

VRF system that can supply heating, cooling, hot

water and now also a supply of electrical power.
Each ECO G Power unit has a 4.0kW generator, which

provides enough electricity to power 8 computers or

other applications.

• Innovative technology that reduces CO

2

emissions by up to

30%

• Heat pump air conditioning system providing cooling

or heating

• Can provide both electricity and hot water in heating and

cooling mode

• Up to 4kW electricity generated

• Very efficient generator

• Hot water provided when cooling or heating when outside

ambient air temperature is above 7°C

• 22kW hot water generation capacity

• 20HP model provides 56kW cooling or 63kW heating

• Can connect to up to 36 indoor units

• 200m maximum allowable piping length (L1) (equivalent - refer
to technical manual)

• IU/OU capacity ratio 50 - 130%

ECO G Power - GHP with electricity generation

& hot water supply

0

10

20

30

40

50

60

70

80

90

100

Air conditioning load (%)

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

Pr

oduc

tion of elec

tr

icit

y (kW

)

Production of electricity

Generates from 2kW to 4kW depending on air conditioning
load

Dimensions ECO G Power

High power

engine

Line linkage

inverter

Power generator

• permanent

magnet type

• non-bearing

Double clutch

compressor

NEW

HP

20

33

36

40

45

Model

SGP-EGW190M2G2W

SGP-EW120M2G2W

SGP-EW150M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EW240M2G2W

Capacity

Cooling

kW

56.0

91.50

101.00

112.00

127.00

Heating

STD

kW

63.0

103.0

113.00

126.00

143.00

Heating Low temp*1

67.0

109.50

120.00

134.00

142.00

Hot water

22.0

34.0

38.0

44.0

47 .00

Power generater capacity at

rating

kW

DC 2.5 (Max 4.3)

Electricity

Cooling

kW

1.35

2.20

2.70

Heating

kW

1.01

2.02

2.55

Gas consumption

Cooling

kW

44.0 (38.3)*

68.50

75.60

88.00

104.90

Heating STD

kW

48.7 (43.0)*

76.80

84.80

97.40

101.00

Heating

LOW

62.1 (56.4)*

98.90

109.40

124.20

121.30

COP Air conditioning only

Cooling

1.33 (1.41)*

1.29

1.23

1.18

Heating

1.34 (1.43)*

1.31

1.30

1.27

1.38

AVE

1.34 (1.42)*

1.30

1.25

1.28

Max COP (Inc generater, hot water)

Cooling

1.78

1.81

1.80

1.78

1.69

Height

Height

mm

2,248

Width

1,800

1,800 + 100 (Min distance) + 1,800

Depth

1,000 (+60)

Weight

kg

875

1,660

1,685

1,740

1,720

Starter amperes

A

30

Pipe

Gas

Inches (mm)

1 1/8 (28.58)

1 3/8 (34.92)

1 5/8 (41.27)

Liquid

5/8 (15.88)

3/4 (19.05)

Balance

3/8 (9.52)

Pipe fuel gas

R3/4 (bolt, thread)

Pipe exhaust drain port

mm

ø25 rubber hose

Operation sound

dB(A)

58

61

63

Indoor/outdoor capacity ratio

50-130%

Number of indoor connections*

32

48

Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.

Please refer to tube sizing charts for pipe selections and pipe length parameters.

Capacity Hot Water is available when outside ambient air temperature is above 7˚C.

Service Clearances for installation

Top View

Rear View

Front View

Left Side View

at least 2000

(Units: mm)

Rear

(refrigerant tubing)

Rear

(refrigerant tubing)

at

le

as

t

60

0

at

le

as

t

60

0

at

le

as

t

10

00

at

le

as

t

10

00

22

50

271

54

147
207
242
275
312

461

27

83

99

13

8

16

3

17

8

19

3

55

5

at least

100

at least

100

1000 (external)

1800 (external)

1040 (suspension holes)

1100 (frame width)

ø736

at least

100

at least

350

400

(1

69

)

22

48

5

10

14

(a

nc

ho

r p

itc

h)

1000

(anchor pitch)

at least

350

Front View

Front View

(Single-unit installation)

(Multi-unit series installation)

Gas refrigerant pipe (Gas tube)

ø28.58

Size (mm)

ш15.88

ш9.52

ш28

ш28

ш20

ш28

ш40

G: R3/4

Rp3/4

Rp3/4

OD:

Length:

1

Liquid refrigerant pipe (Liquid tube)

2

Refrigerant balance pipe (Balance tube)

3

Exhaust gas drain hose

4

Electrical power supply port

5

Inter-unit cable port

6

Inverter cable port

7

Inverter cable port

8

Fuel gas port

9

Condensation drain opening

10

Rain and condensation outlet

11

Engine exhaust outlet

12

Suspension holes 4 - ø20

13

Anchor holes 4 - ø24

14

Segment display

15

Coolant intake (top)

16

Vent

17

Hot water intake

18

Hot water outlet

19

12

14

16

9

11

17

13

15

8

3

4

2

10

1

19

18

7
5
6

Generate electricity during heating or cooling

operation

Generate electricity and air conditioning (heating or cooling)
at the same time by using remaining engine power. ECO G
Power can generate from 2.3 to 4.0kW electricity at a generation
efficiency of more than 40%.