Gu type heat exchanger & cfr units, Additional ghp functions – Sanyo ECO G SGP-EZ190M2G2 User Manual

Page 6

Advertising
background image

10

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

11

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

System configured at site

Main

Hot Water

Boiler

Hot water inlet: Rø3/4
Hot water outlet: Rø3/4

Hot Water

Storage

Tank

Water piping

GHP

OUT

IN

GU Type Heat Exchanger & CFR Units

SANYO’s new heat recovery ventilation system allows

total control via a system network whilst modulating the

temperature and humidity of incoming air supply.

• Integration of heat recovery ventilation and DX coil technology

for optimum air temperature control

• Connects to all ECO & GHP outdoor units with a filter option

• 3 Way: Solenoid valve kit is required for each unit

• 2 Way: RAP kit is required for each unit

Indoor unit specifications

Model Name

SPW-GU055XH

SPW-GU075XH

SPW-GU105XH

Air circulation (H) m³/h

500

750

1,000

Power source

220/230/240V, 1 phase - 50 Hz

Fresh air load

treatment capacity

UK Cooling

kW

5.3 (1.7)*¹

8.2 (2.6)*¹

10.7 (3.4)*¹

UK Heating

kW

6.5 (2.3)*¹

9.8 (3.5)*¹

12.6 (4.6)*¹

Enthalpy exchange

efficiency

UK Cooling

%

59

UK Heating

%

67

Temp exchange efficiency

75

Equivalent cooling capacity

kW

3.6

5.6

7.3

BTU/h

12,000

19,000

25,000

Power input

Cooling

kW

0.532

0.737

0.798

Heating

kW

0.532

0.737

0.798

Running current

Cooling

Amps

2.4

3.2

3.5

Heating

Amps

2.4

3.2

3.5

Fan motor

Type

Sirocco fan

External static pressure-return air

Pa

183 (170)

221 (188)

135 (88)

External static pressure-supply air

Pa

205 (182)

264 (218)

176 (137)

Output

kW

0.28 (4P)x2

0.35 (4P)x2

Sound pressure level (C/H)

db(A)

46 (Cooling), 47 (Heating)

47 (Cooling), 48 (Heating)

48 (Cooling), 49 (Heating)

Dimensions

Height

mm

425

450

Width

mm

1785

1903

Depth

mm

1000

1120

1220

Piping connections

Liquid (flare)

mm (inches)

6.35 (1/4)

Gas (flare)

mm (inches)

12.7 (1/2)

Drain piping

VP-25

Connection duct diameter

mm

250

300

Net weight

kg

134

153

168

The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.

The CFR- PHE uses a unique purifying Bioxigen system to

produce negative ions this can reduce pollutants by up to

85% whilst improving, significantly air quality within most

environments.

• High efficiency heat exchanger & Easy to clean filters

The CFR-PHE unit structure is constructed from Aluzink frame
work and galvanised steel with 20 mm thick fire resistant
acoustic insulation, reducing both weight and sound levels to
a minimum. The system is supplied with ducted spigots which
can be positioned either at the front or side of the unit to ease
installation.

Indoor unit specifications

Model CFR/ CFR-PHE

33

55

110

175

220

Nominal air flow *

m3/hr

300

620

920

1580

1850

External Static Pressure

pa

45

55

65

70

77

Sound Pressure **

dB(A)

43

51

50

53

52

Fans
Power in

Watts

184

340

294

700

700

Absorbed power

A

0.75

1.8

2.2

4.4

4.8

Fan speeds

no

1

3

Insulation Class

F

Electrical supply

v/ph/htz

230/1/50

Bioxigen Elements (PHE only)
Number of elements

2 X C

2 X F

Electrical supply

v/ph/htz

230/1/50

Power in

Watts

8

8

8

8

8

Filter

EU3

Paper Heat Exchanger

CFR-PHE

Temperature Efficiency heating ***

76%

74%

72%

68%

73%

Temperature Efficiency cooling ****

62%

60%

58%

54%

59%

* Nominal air flow ** Sound pressure 1.5 mts from the unit in free field *** Data referred to -5

0

C 80% RH OAT room condition 20

0

C 50% RH **** Data referred to 32

0

C 50% RH OAT room condition 26

0

C 50% RH

The high efficiency low pressure loss total heat exchanger
is made of specially treated paper to enable the unit to be
as efficient as 76% during normal operation. This allows
system to recover both latent and sensible heat.

Additional GHP Functions

GHP Chiller available with outdoor unit capacities from 71kW

Water Heat Exchanger

Air Handling Unit

Water Piping

Duct

Outdoor unit

Operating condition

Cooling

Heating

(standard)

Heating

(low temperature)

Water temperature of water heat exchanger unit Outlet 7°C

Outlet 45°C

Outlet 45°C

Outdoor side intake air temperature

35°C DB

7°C DB, 6°C WB

2°C DB, 1°C WB

Note: The gas consumption can be 110% of the specification value depending on the

operating conditions.

The SANYO ECO G Water Heat Exchanger can provide

water at a wide range of temperatures suitable for a

variety of commercial applications ranging from comfort

air conditioning to food processing or the replacement of

boilers and other systems.

• New 25 kW and 50 kW capacity models

• In cooling (chiller) mode provides water from -15°C to 15°C

• In heating mode can provide hot water up to 55°C, for example

for under floor heating applications

• Includes water flow protection to prevent freezing

• Temperature sensor included

• S-Link communication is connectable with any controllers

• Split system means reduced installation cost and the use of a

less powerful circulation pump

• One touch changeover between cooling and heating operation

• The system can accommodate up to 120m (actual length) of

piping between the outdoor unit and the water heat exchanger,
allowing flexibility of installation location

• The system uses antifreeze coolant, so it can produce cold water

even at -15°C, thereby complying with “brine specifications”

Model No.

SGP-WE80M1

SGP-WE170M1

SGP-EW120M2G2W

Cooling capacity

kW

25

30

Heating capacity

kW

30

35.5

SGP-EW150M2G2W

Cooling capacity

kW

25

37.5

Heating capacity

kW

30

45

SGP-EW190M2G2W and

SGP-EGW190M2G2W

Cooling capacity

kW

25

50

Heating capacity

kW

30

60

SGP-EW240M2G2W

Cooling capacity

kW

25

56

Heating capacity

kW

30

67

Electrical rating

Cooling power input kW

0.01

Heating power input kW

0.01

Power supply

220/230/240V Single Phase 50Hz

Size

Height

mm

1,000

Width

mm

550

Depth

mm

965

Weight

kg

125

160

Standard cold/hot water flow rate

m

3

/h

4.3

8.6

Hydrostatic loss

kPa

8.5

11.3

Holding water quantity inside the unit

m

3

0.01

0.02

Minimum holding water quantity outside the unit m

3

0.28

0.50

Piping refrigerant

Gas pipe

mm

ш22.22

ш28.58

Liquid pipe

mm

ш9.52

ш15.88

Heat exchanger

hot/cold heat exchanger

Water circuit limit pressure

MPa

0.686

Anti-freezing protection system

Protective thermostat

Specifications subject to change without notice.

Hot water supply function (during cooling or heating operation)

SGP-EW120M2G2W

SGP-EW150M2G2W

SGP-EW190M2G2W

SGP-EW240M2G2W

SGP-EGW190M2G2W

The engine waste heat, which is normally exhausted into
the atmosphere, is recovered via the heat exchanger and
effectively used as hot water, so the GHP system acts as a
subsystem that alleviates the load on the client’s main hot
water system and therefore offers “free” hot water.

Water heating capacity up to 65 kW (of 75°C hot water)
Hot water piping allowable pressure 0.7 MPa
Hot water circulation rate 2 - 3.9m

3

/h

Hot water pipe size 3/4 inch

Advertising