Installing the Mounting Brackets Onto the Server

Use this procedure to install the mounting brackets onto the sides of the server.

1. Position a mounting bracket against the chassis so that the slide-rail lock is at the

server front, and the three keyed openings on the mounting bracket are aligned
with the three locating pins on the side of the chassis. See

FIGURE 1-2

.

FIGURE 1-2

Aligning the Mounting Bracket With the Server Chassis

2. With the heads of the three chassis locating pins protruding though the three

keyed openings in the mounting bracket, pull the mounting bracket toward the
front of the chassis until the mounting-bracket clip locks into place with an
audible click. See

FIGURE 1-2

.

3. Verify that all three locating pins are trapped in the keyed openings and that the

rear locating pin has engaged the mounting-bracket clip. See

FIGURE 1-2

.

4. Repeat the procedure to install the remaining mounting bracket on the other side

of the server.