Connecting to the ILOM Service
Processor

There are two methods for connecting to the ILOM SP to perform initial setup and
configuration. Use the procedure that you prefer:

“Connecting to ILOM Using a Serial Connection” on page 21

“Connecting to ILOM Using an Ethernet Connection” on page 23

Connecting to ILOM Using a Serial Connection

Use this procedure to establish a serial connection to the ILOM SP so that you can
perform initial configuration of ILOM.

Note –

This procedure assumes that you have already completed the hardware

setup and have applied standby power to your server, as described in

Chapter 1

.

1. Verify that your terminal, laptop, or terminal server is operational.

2. Configure that terminal device or the terminal emulation software running on a

laptop or PC to the following settings:

8N1: eight data bits, no parity, one stop bit

9600 baud

Disable hardware flow control (CTS/RTS)

Disable software flow control (XON/XOFF)

3. Connect a serial cable from the RJ-45 SERIAL MGT port on the server’s back

panel to a terminal device.

See

FIGURE 1-11

or

FIGURE 1-12

for the location of this port.