Recording area set, Menu setting procedures – Sanyo DSR-3009 User Manual

Page 11

Advertising
background image

10

English

Menu Setting Procedures

The hard disk in this unit consists of three independent recording areas, each of which has five recording
modes.
A percentage of the total recording capacity is allocated to each recording area (settings are in units of
1%).

1

Total capacity display

Displays the total capacity of the hard disk.

2

Capacity display for each recording area

The recording capacity of each recording area of the digital
video recorder’s hard drive is displayed as a percentage of
the total capacity.

3

Recording area reset

If the OVERWRITE setting is “OFF”, recording will stop
automatically when a recording area becomes full. If when
[AREA FULL RESET] has been selected, the recordings that
have been made will be deleted and recording will begin
again from the start of the recording area.

4. RECORDING AREA SET

Recording area

Recording mode

Notes

NORMAL RECORDING
AREA

Normal recording

Manual

Recording is carried out manually using the

O

button.

Timer recording

Automatic

Recording is carried out automatically within
the time range specified by the timer
recording setting made using the menu
screen.

ALARM RECORDING AREA

Alarm recording

Automatic

Recording is carried out automatically when
an alarm is detected according to the alarm
recording settings made using the menu
screen.

Pre-alarm
recording

Automatic

Images that are around the time that the
alarm was detected are recorded
automatically according to the pre-alarm
recording settings made using the menu
screen.
This is used as a complementary function to
alarm recording.

ARCHIVE AREA

Copy

Manual

Copies and saves essential recordings from
another recording area by using the

M

button on the operating panel manually.

If two hard disks have been installed and the digital
video recorder’s HDD SET function has been used
to set mirroring to “ON”, the details for the disk with
the smaller capacity will be displayed.

The capacities of the recording areas cannot be set
and changed from a connected computer.

If the recording capacity for the normal recording
area and the alarm recording area have been set to
0% and if the OVERWRITE setting is “OFF”, there is
no need to use the reset function, and so the AREA
FULL RESET button will not appear on the screen at
such times.

1

2

3

L8HBA_US(DSR-3016 NETWORK)(GB only).book 10 ページ 2003年3月28日 金曜日 午後6時44分