Troubleshooting – Sub-Zero 315 User Manual

Page 20

Advertising
background image

20

TROUBLESHOOTING

Problem

Possible Cause

Probable Correction

The ice maker does not operate

The ice maker is unplugged

Plug the ice maker in

Breaker tripped or fuse is blown

Reset breaker/replace fuse – if it happens again,
call for service to check for a short circuit in the
ice maker

Ice maker control turned to OFF

Turn ice maker control to ON

Bin thermostat open, keeping

Ice on sensor tube – its then

ice maker off

normal for the ice maker to be off

Ice maker in a room below 50˚F – room needs
to be warmer for ice maker to operate.

Bin thermostat stuck open, needs to be replaced.

Timer contacts open

Replace timer

Cubes are too big

Cube size control set too cold

Adjust cube size control for a smaller cube

Cubes are too small

Cube size control set too warm

Adjust cube size control for a larger cube

Not enough water

Check water supply – filter may be restricted

Check inlet water valve – inlet screen may be
restricted

Cube size control stuck closed –

Replace timer

timer runs all the time.

Cubes are partially formed –

Spray jets partially clogged

Clean ice making system with ice maker

have ragged sides

cleaner.

Ice maker makes ice, but bin

The bin should fill up and the

Clean the condenser.

does not fill up with ice

ice maker shut off in 24-36 hours.
If not, the condenser may be dirty

The bin drain may be partially

Clean out the drain, check the installation.

restricted

The air flow to the ice maker

Check the installation – the ice maker must be

may be obstructed

free of obstructions at the kickplate.

Cubes are partially formed –

Not enough water in the reservoir.

Check water supply – filter may be restricted

are white at the bottom

Check inlet water valve - inlet screen may be
restricted.

Check for a water leak at the reservoir.