TROUBLESHOOTING

Problem

Possible Cause

Probable Correction

No ice falling in bin, but

Ice may be stuck in the

Check water supply – filter may be restricted

ice maker operates

evaporator and the unit is
"frozen up"

Check inlet water valve – screen may be
restricted, or valve does not operate

Hot gas valve may not operate -check and
repair/replace

Harvest time set too short – timer needs
adjustment

Too much heat load

Inlet water valve leaks through, needs to be
replaced

No water spray

Water pump does not work, replace it

Water leak from reservoir, locate and repair

Cube size control will not close

See "Too much heat load" or "not enough
refrigerant"

Control defective - must be replaced

No airflow

Fan motor not turning, needs to be replaced

Fan blade broken, needs to be replaced

Condenser completely blocked up, needs cleaning

Not enough refrigerant

Add low side access valve, locate leak, recover
refrigerant, repair, replace dryer, evacuate and
weigh in the nameplate charge

Restricted system

Add low side access valve, recover refrigerant,
replace dryer, evacuate and weigh in the
nameplate charge

Hot gas valve leaks through

Add low side access valve, recover refrigerant,
replace hot gas valve and dryer, evacuate and
weigh in the nameplate charge

Compressor will not operate or

Start relay or capacitor needs to be replaced

pumps poorly.

Add low side access valve, recover refrigerant,
replace compressor and dryer, evacuate and
weigh in the nameplate charge.